SASIG - Strategic Automotive product data Standards Industry Group
 

News

Home | Publications | Activities | Member Login | Links | Contact | Imprint
05. November 2008
SASIG PDQ Workshop Paris 13.-15. October 2008


The 2008 SASIG PDQ Workshop took place in Paris in the middle of October. This workshop was the final one, the group finished its work with this meeting.
The two main issues were presentations of t...
[more]


23. July 2007
SASIG PDQ Workshop Kyoto 15.-17. October 2007


The 2007 SASIG PDQ Workshop took place October 2007, 15th to 17th at Kyoto, Japan. Conformance Test result review was the main issue on the agenda.

[more]


07. May 2007
SASIG PDQ Workshop Stockholm 16.-18. April 2007


As announced before, the SASIG PDQ Conformance Test result review was the main issue on the agenda. Two candidates have performed that test prior to the meeting, one has passed the review with success...
[more]


06. March 2007
Announcement: SASIG PDQ Workshop Stockholm 16.-18. April 2007


Although the PDQ WG has skipped the Fall Workshop 2006 the next meeting will take place in spring this year. Even if the meeting schedule is not fixed yet, the main issue for this meeting is clear:...
[more]


Conformance Test Results

Select Checktool:

 
Summary of check Protocol CATIA V5 non-geometric criteria
 
General Information Geo Non-Geo Diagram

*Although they are mandatory criteria, the three criteria "O-CM-AP", "O-CS-SU" and "O-CS-SS" have not been evaluated since those three criteria are not relevant for CATIA V5 releases available at the time of the conformance test.

Criterion Criterion Name Status Check function LEVEL*
(1,2,3)
Healing function available
(Yes/No)
remarks
O-CM-CV Non-standard CAD version mandatory 1 No  
O-CM-SE Wrong CAD startup environment  mandatory 1 No  
O-CM-SC Special character used in CAD model name mandatory 1 No  
O-CM-IN Non-standard item name mandatory 1 Yes  
O-CM-PN Non-standard physical file name mandatory 1 No  
O-CM-IC Item data consistency incorrect mandatory 1 No  
O-CM-UP Unused encapsulated entities present mandatory 1 Yes delete
O-CM-EI External item reference mandatory 1 Yes  
O-CM-IR Inconsistent item reference mandatory 1 Yes delete
O-GL-LU Non-standard layer usage mandatory 1 Yes  
O-GL-LA Non-standard layer group mandatory 1 Yes  
O-CS-NO Non-standard co-ordinate system orientation mandatory 1 No  
O-AR-AR Assembly relationship used mandatory 1 No  
O-SO-HN History not used mandatory 1 Yes delete
O-SO-HU History not updated mandatory 1 Yes  
O-SO-MH Missing solid construction history mandatory 1 No  
O-FE-UF Unresolved feature used mandatory 1 No  
O-FE-IF Inactive feature used mandatory 1 Yes  
O-EL-PE Prohibited element used mandatory 1 No  
O-EL-UD User-defined element used mandatory 1 No  
O-SK-NC Not fully constrained sketch mandatory 1 No  
D-OR-SC ISO conformable texts mandatory 1 No  
D-OR-DU 2D drawing not updated mandatory 1 Yes  
D-OR-PF Missing plot frame points mandatory 1 No  

* Definition of Level

  Judgement Level 3 Level 2 Level 1
Check function All "Off tolerance" elements are detected, no "In tolerance" element is detected. Y Y Y
SASIG criteria encoding is used. N Y Y
The measurement defined in the Guideline is used. N N Y
         
A criterion is checked "Level 1", if all three adjectives have been validated "Yes".
 
Seite druckenprint